RELEASE HISTORY FOR ALPS

 

Quick Access Links

 

ALPS EL, LT and NT

ALPS PC

 

 

Release 2.40

Release 1.30

Release 2.30

Release 1.24

Release 2.20

Release 1.23

Release 2.10

Release 1.22

Release 2.00

Release 1.21

Release 1.13

Release 1.20

Release 1.12

Release 1.18

Release 1.11

Release 1.17

 

Release 1.16

 

Release 1.15

 

Release 1.14

 

Release 1.13

 

Release 1.12

 

Release 1.11

 

Release 1.10

 

Release 1.01

 

Release 1.00

 

Release 0.72

 

Release 0.71

 

Release 0.70

 

Release 0.64

 

 

 

 

ALPS EL, LT and NT

ALPS LT, NT Release 2.40

General

·         It is no longer required to log on as a Windows NT Administrator

·         It is no longer required to use the same (Windows NT) user name everywhere

o        This solves the problem of the two sort icons

·         For almost all paths (file-sharing), the user can specify a Windows NT user.

·         Any table can be navigated (moving from one column to another) by using the TAB key as well, in the previous version it had to be the arrow key.

·         The screen navigation has improved. When navigating between the three groups, ALPS no longer navigates back to the default (first screen) screen. Instead, it navigates to the last one shown of that group.

Import Screen

·         Set Path button behaviour has changed. Pressing this button shows the same window but any changes made will only be made for the current ALPSGUI session. The paths are no longer saved. In the previous version you could save the default path’s on the system setup and on the import screen. It makes more sense, and it’s clearer, to allow this only on the system setup screen.

Shipment Screen

Run Screen

Map Screen

Product Setup Screen

History screen

Purge Screen

Sort Screen

Die-pick screen

New Wizard setup screen

New Notify Screen

System Setup

Security

New equipment monitor ‘look’

Datacon driver

Back to top of page

ALPS LT, NT Release 2.30

Shipment Screen

Map Screen

Product Setup Screen

History Screen

Sort Screen

Purge screen

Security Screen

Format Screen

Map Versions (Import and Sort screens)

Run Screen

Drivers

ALPS API

General

Back to top of page

ALPS LT, NT Release 2.20

General

Purge Screen

System Screen

DiePick Screen

Equipment Monitor

Equipment Manager

SECS Driver

ALPS Sort

Back to top of page

ALPS LT, NT Release 2.10

Import on Demand

Automatic Purge

General

Map Screen

Equipment Monitor

Mapview

AlpsPurge

Back to top of page

ALPS LT, NT Release 2.00

General

Login Window

Import Screen

History Screen

Transfer Screen

Product Setup Screen

Run Screen

Map Screen

Security Screen

Format Screen

Filter Window

DiePick Screen

Equipment Monitor

Equipment Manager

SECS Driver

ALPS Sort

Datacon support

Back to top of page

ALPS LT, NT Release 1.13

Wafer Map zoom function

Print function

Importing with ftp

Importing with ftp is also supported by ALPS Sort.

Reference die positioning

Map screen information

Back to top of page

ALPS LT, NT Release 1.12

General

Product Setup Screen

Map Screen

Format Screen

DiePick Screen

Equipment Monitor

SECS Driver

ALPS Sort

ALPS Die Pick

Back to top of page

ALPS LT, NT Release 1.11

General

Login Window

Import Screen

History Screen

User Info Screen

Product Setup Screen

Run Screen

Map Screen

System Screen

Security Screen

Format Screen

Filter Window

DiePick Screen

Equipment Monitor

SECS Driver

ALPS Sort

Die Pick

Back to top of page

ALPS PC

ALPS PC Release 1.30

Back to top of page

ALPS PC

ALPS PC Release 1.24

Back to top of page

ALPS PC Release 1.23

Back to top of page

ALPS PC Release 1.22

Back to top of page

ALPS PC Release 1.21

Back to top of page

ALPS PC Release 1.20

Back to top of page

ALPS PC Release 1.18

BACKUP makes a diskette backup of a complete ALPS PC installation on a  computer, including  - all configuration changes in .BTC files - all configuration settings made in the ALPS PC Setup Service - all installed ALPS PC converters, with customized color settings but NOT including any wafer and lot information.

The produced backup diskette will contain a program called RESTORE. It can  be used to re-install a specific, completely backed-up ALPS PC installation  from diskette.

Back to top of page

ALPS PC Release 1.17

Back to top of page

ALPS PC Release 1.16

Back to top of page

ALPS PC Release 1.15

Back to top of page

ALPS PC Release 1.14

Back to top of page

ALPS PC Release 1.13

Back to top of page

ALPS PC Release 1.12

·         This version contains a few small improvements, based on field-tests of the Automatic Import Option.

Back to top of page

ALPS PC Release 1.11

·         The Reports setup file REPORTS.BTC has been replaced by a set of  R_xxxxxx.BTC files, one for each die bonder type supported.

·         Implemented in ALPS PC 1.11 are:

o        R_ALPHAS.BTC for Alphasem die bonder type

o        R_ESEC.BTC for ESEC and ESEC_OLD die bonder types (do not use a Reports file for ESEC_2006!)

o        R_ASM.BTC for ASM die bonder type

o        R_VIKING for VIKING die bonder type

Back to top of page

ALPS PC Release 1.10

·         The Wafer Map Editing Option has been implemented. It is provided as a separate Map Editor Operation under the Data Services.

·         A more general implementation of the Material Tracking Option has been made, allowing the user to specify a directory to which the die - package files  will be written. This function has furthermore been integrated with the  Export function, provided on the Wafer and Lot Data Operation.

·         Adding and removing format converters has been removed from the System  Setup Operation and is now part of the new Format Setup Operation (Setup  Service). This Operation also allows the user to specify for each map  format the colors used by ALPS PC to present the bin codes. These color  settings can be saved on the Format Diskette.

·         The Wafer Mount Operation now allows to mount wafers on frames without  assigning the wafers to a lot. In the lot pull-down list select "<no lot>".

·         Die bonder communication has been made much more robust. ALPS PC now tries  to establish communication automatically on start-up, monitors that  communication is still present once a connection has been established, and  offers a facility to the user (CONNECT button on the Die Bonder Status  Operation) to try to re-establish communication.

·         ALPS PC now supports die bonder requests for date and time (SECS-II  messages S2F17/F18).

·         Like the other Operations which can show zoomed-in wafers, this feature has  been added to the Die Bonder Status Operation.

·         ALPS PC now supports sending setup information to the die bonder, based on  settings defined by the user in the Product Setup Operation. This  information includes bin codes to be bonded, null bin code, reference die  coordinates. The definitions made in the Product Setup Operation are valid  per lot.

·         The READ function can now input data from an old version database.

·         In the file PRINTERS.BTC it is now possible to include a printer setup  string, which will be sent to the printer on initialization. This allows to  set the right paper orientation, font, etc., dependent on the type of  printer used.

·         Error reporting by ALPS PC in the ALPS PC.LOG file has been made much more  robust, so that no information gets lost in case of a crash.

·         All bugs and cosmetic issues, reported by May 1, 1997 have been solved.

Back to top of page

ALPS PC Release 1.01

·         Memory use has been reduced to ~10MB, well below the 12MB boundary, which was just passed in ALPS PC 1.00.

·         ALPS PC now accepts any Collection Events the die bonder may send. If the event (CEID) is unknown to ALPS PC, because it cannot be found in the file REPORTS.BTC, then a negative acknowledge is sent to the die bonder. To prevent these NACKs, the user can add events to the file REPORTS.BTC.

·         ALPS PC 1.00 did a status check on the text printer connected. This has been removed again, because it does not work with various printers.

·         A bug was fixed in the SECS-II communication with the die bonder, causing problems with a zero number of SECS-II items in messages.

·         A bug was fixed, regarding the incorrect display of large dies on the zoomed-in wafer map display.

·         When no wafer is selected in the Map Data Option, the ZOOM button is now disabled.

·         The Die Bonder Status Operation showed incorrect wafer map header items. This has been corrected.

·         The Format name, shown in the Wafer Data Operation, was incorrect. This has been fixed.

·         REMOVE format in the System Setup Operation did not work. This has been corrected.

·         ADD format did not work for the "Example 1.0" wafer map format. This has been corrected.

·         After entering information on the Product Setup Operation screen, leaving the screen and going back to it, the earlier entered information is now still present.

·         A problem was fixed, causing wafer map upload to fail when the wafer map setup information (S12F1) contained more than one reference die position.

Back to top of page

ALPS PC Release 1.00

·         Lists of installed converters now also show the version numbers.

·         The maximum length of directory paths in the System Setup has been considerably increased.

·         The Wafer Setup Operation allows to specify the wafer map origin.

·         It is now possible to select "no die" positions in displayed wafer maps.

·         The die coordinate system, used by ALPS PC, has been adapted to the SECS-II standard.

·         The handling of reference dies has been made more flexible and die bonder dependent.

·         The Die Bonder Status Operation now shows the wafer with the flat orientatation it has on the die bonder.

·         A bug has been solved with the handling of the Assign radio buttons on the Lot Data Operation.

·         A bug has been solved with a premature abort of ALPS PC after initial start-up, causing ALPS PC not to start up anymore afterwards.

·         A bug has been solved, related to the creation of an ALPS PC database in an incorrect directory.

·         The number of wafer map header items has been increased from 16 to 64.

·         A minor bug has been solved with an incorrect number of dies being shown on the Map Data Operation, after upload of a new version of the map.

·         Handling of locked and (suddenly) missing diskettes has been improved.

·         A serious bug has been solved, caused by the continous increase of the number of open files, each time a wafer map was uploaded. This caused ALPS PC to crash after a certain period of operation.

·         Print facilities for lots, wafers and wafer maps has been implemented.

·         The Print Bar Code function has been implemented for Frame ID labels. This implementation allows to connect any kind of bar code printer, but requires some printer-specific code to be written. Currently this printer-specific part is available for the Intermec 3400.

·         The Wafer Map History Option has been implemented.

·         The Product Setup Operation has been implemented. This Operation assists the operator with the setup of the die bonder to process a batch of wafers, by selecting reference die coordinates, bin codes to be bonded, specifying the no-die bin code, etc.

·         The wafer map, displayed in the Map Data Operation and Product Setup Operation can be enlarged to use the full screen height. This allows the easy viewing and selecting of small dies (down to less than 1 mm dies on 200 mm wafers).

·         The Material Tracking Option has been implemented.

Back to top of page

ALPS PC Release 0.72

Back to top of page

ALPS PC Release 0.71

Back to top of page

ALPS PC Release 0.70

Back to top of page

ALPS PC Release 0.64